Roadside

Category

System

Installation Manual

Manufacturer

Name

Drawing Number

Sheets in Drawing

A

Trend 350
2

Trend 350 Install Manual

Trinity Industries
Criteria:
a) W beam guardrail end treatment
b) NCHRP 350 TL3 approved
c) Gating, redirective system
d) Roadside installation offset between 0 mm and 1219 mm over required length of system (11.43 m)
e) Installation height of 550 mm at centreline

 

 

 

   

 

B

X-Lite (Flared)
2
Barrier Systems
SRT-27
1
Trinity Industries
SRT-350 (6 post)
1
Trinity Industries
Criteria:
a) W beam guardrail end treatment
b) NCHRP 350 TL3 approved
c) Gating, redirective system
d) Roadside installation offset of 1219 mm over required length of system (11.43 m)
e) Installation height of 550 mm at centreline

 

 

 

   

 

C

FLEAT 350
1

FLEAT 350-SP Install Manual

Road Systems
FLEAT 350
1

FLEAT 350-W Install Manual

Road Systems
SRT-350 (8 post)
1

SRT-350 8 Post Install Manual

Trinity Industries
Criteria:
a) W beam guardrail end treatment
b) NCHRP 350 TL3 approved
c) Gating, redirective system
d) Roadside installation offset between 762 mm and 1219 mm over required length of system (11.43 m)
e) Installation height of 550 mm at centreline

 

 

 

   

 

D

SKT 350
1

SKT Install Manual

Road Systems
SKT 350
1

SKT Install Manual

Road Systems
X-Lite Tangent
2

X-Lite Tangent Install Manual

Barrier Systems
ET Plus (Steel)
1

ET Plus Install Manual

Trinity Highway Products
ET Plus (Wood)
1

ET Plus Install Manual

Trinity Highway Products
Criteria:
a) W beam guardrail end treatment
b) NCHRP 350 TL3 approved
c) Gating, redirective system
d) Roadside installation offset between 0 mm and 610 mm over required length of system (15.24 m)
e) Installation height of 550 mm at centreline
 
 
 
   
 
E
X-MAS
composite blockouts
1
Barrier Systems
X-MAS
wood blockouts
1

Barrier System

CAT 350
1
Trinity Industries

Criteria:
a) W beam guardrail end treatment along pedestrian facilities
b) NCHRP 350 TL -3 approved
c) Gating or non-gating, redirective system
d) Installation height of 550 mm to centreline at downstream end
e) Connects to standard guardrail using standard hardware at downstream end
f) Guardrail section(s) are placed on both sides of the system for its entire length
g) Guardrail section(s) are not extruded when impacted at the upstream end
h) No foundation pad is required