Median

Category System Installation Manual Manufacturer
Name Drawing Number Sheets in Drawing

Reusable

X-MAS
composite blockouts

XTMTSS3

1

X-MAS
Installation Manual

 Barrier Systems

X-MAS
wood blockouts
XTMTSS2 1 X-MAS
Installation Manual
 Barrier Systems
FLEAT MT
steel posts

MEDFLT-S

1

FLEAT-MT Installation Manual

Road Systems

FLEAT MT
wood posts
MEDFLT-W 1 FLEAT-MT Installation Manual Road Systems
CAT 350

SS-245

1

CAT 350
Installation Manual

Trinity Industries

Criteria:
a) NCHRP 350 TL3 approved
b) Median W beam guardrail end treatment
c) Gating or non-gating, redirective system
d) Installation height of 550 mm at centreline at downstream end
e) No foundation pad is required.

 

 

 

 

 

 

Repairable

TAU-II

30T100CBC

1

TAU-II Installation Manual

Barrier Systems

X-TENuator

XTEN100N

4

X-TENuator Installation Manual

Barrier Systems

QuadGuard

QSTSCVR-U

1

QuadGuard
Installation Manual

Energy Absorption

QuadGuard II

QG2TSCVR-U

1

QuadGuard II Installation Manual

Energy Absorption

TRACC

SS 1003

1

TRACC Installation Manual

Trinity Highway Products

Smart Cushion

ET0604NT_TL III

1

Smart Cushion Installation Manual

Work Area Protection

Criteria:
a) NCHRP 350 TL3 approved
b) Fender panels cascade rearwards when impacted at the nose
c) With our without replaceable energy absorbing cells
d) Stand alone system or connects to standard guardrail or concrete barrier with special transition hardware available as additional components
e) Non-gating, redirective system
f) Requires concrete or asphalt pad

 

 

 

 

 

 

Low Maintenance

TAU-II-R

30TR100CBC

1

TAU-II-R
Installation Manual

Barrier Systems

QuadGuard Elite

QL3TSCVR8-U

1

QuadGuard Elite Installation Manual

Energy Absorption Systems

Compressor

600-114

1

Compressor Installation Manual

TrafFix Devices

HEART

SS 1518

1

HEART
Installation Manual

Trinity Highway Products

Criteria:
a) NCHRP 350 TL3 approved
b) Steel fender panels, High Density Polyethylene fender panels and/or steel diaphragms
c) Fender panels, when present, cascade rearwards when impacted at nose
d) Reboundable High Density Polyethylene, or equivalent, components
e) Stand alone system or connects to standard guardrail or concrete barrier with special transition hardware available as additional components
f) Non-gating, redirective system
g) Requires concrete or asphalt pad

 

 

 

 

 

 

Self - Restoring

REACT 350

R62B036

1

REACT 350 Installation Manual

Energy Absorption Systems

REACT 350 II

6 Cyl TL-3 REACT

2

REACT 350 II Installation Manual

Energy Absorption Systems

Criteria:
a) NCHRP 350 TL3 approved
b) Reboundable High Density Polyethylene, or equivalent, components
c) Side cables to contain system and provide redirection
d) Stand alone system or connects to standard guardrail or concrete barrier with special transition hardware available as additional components
e) Non-gating, redirective system
f) Requires concrete or asphalt pad or drivable pile anchor system